Magne-Flo

Tell a Friend Bookmark Page Print Page

Technical Information



 

Carbon Monoxide Detector

Control Panel

Power

230v AC

230vAC 500mA


Power Consumption

<3W

<2W


Environment

Temp – 0-55°C Humidity - <95%

Temp – 0-55°C Humidity - <95%


Response Time

<30 seconds

<5 seconds


Alarm

Visual & Audible (90 db)

Visual only


Weight

270 g

128 g


Size

126 x 78 x 37 mm

110 x 84 x 40 mm


Frequency

433 MHz

433 MHz


Range

200 meters in Open Ground


Approvals

Carbon Monoxide Detector EN50291 Combustible Gases Detector EN50194

 


The Flowtechsystem is designed to provide Visual and Audible Alarms in line with EN50291and EN50194 levels and close the gas supply to prevent further build up. Inboth cases the gas supply will be closed within 45 seconds of the alarm levelbeing reached.

 

Gas Meter Control Lever Shut Off


Environment

Temp : -10-50°C Humidity - <95%


Torque

30-60 kg cm


Reset

Reset button on Control Panel or Manual on device


Closing Time

5-10 seconds


Rated Voltage

12vDC


Operating Voltage

6v-18v DC


Rated Power

1.2W


 

 


Gas Meter Control Lever Shut Off

Gas Meter Control Lever Shut Off issupplied with 2 sizes of Mounting bracket to match with the Gas Meter Controlvalve size and receives 12v DC supply from the Control Panel link only whenrequired to close the gas supply.


The Gas Meter Control Lever ShutOff device is easily mounted onto the Lever control and requires nointerruption of the gas supply line and no engineer to install it.


Pulse Valve


Quiescent Working Current

0A


Rated voltage for valve close

DC9~12V


Resistance of loop in valve-closed

4.5Ω±0.5Ω


Diameter

G1/2 and G3/4


Response Time from pulse to closed

<0.3 sec


Operating Temperature

-15°C - 50°C


The Flowtech System can also control a 12v DC Pulse Valve fitted into the gas line which is sent a power pulse on a 30 second cycle in the event of an alarm.
 
 
 

Edit this page